Introducing the AQcontroller V2
IoT AQcontrollers
Summaryof Key Benefits
Built in Wifi and GSM Module.
Remote programming and monitoring as standard.
Remote access via our web browser or mobile app.
Analog output as standard (4-20 mA) for ORP control of system halogen reserve.
Economical wall mounted package for easy installation.
Four relay outputs for increased flexibility.
Complete flexibility in fuction of each relay:
On / Off Setpoint Time Proportional Control In Range or OUt of Range Activation Timer-based activation Flow control Meter controlDatalogging
Emailing Alarm messages, Datalog reports and System summary reports.
The AQcontroller is now discontinued.
Warranty Coverage: If your V1 is still within the warranty period, you are eligible for warranty-covered components and repairs.
Out-of-Warranty Support: If your V1 is no longer under warranty but you require components or repairs, we still have stock available and will be able to support all existing customers.
If you would like to upgrade your V1 to a V2 variant, we will be able to upgrade your unit for a nominal fee. Please contact our sales department for further information.
Specifications
Inputs
110-240 VAC, 50 or 60 Haz, 10A MAx Fuse: 6.3 Amp
-
•Accuracy: ±1cm
•Average Current: <15mA
•Blind Zone: 5cm
•Detection Range (Flat Object): 5-750cm
•Output: Isolated 4-20mA
•Response Time: 100ms
•Probe Center Frequency: 40K±1.0KHZ
•Operating Temperature: -15~60℃
•Storage Temperature: -25~80℃
•Sensing Angle: with bell-mouth: 55º
•without bell-mouth: 40º
•Waterproof Grade: IP67
•Resolution: 1mm -
•Probe Type: Industrial Grade
•Excitation/Emission: 410nm
•Detection Range: 0-200ppb
•Temperature Range: 0~60°C
•Accuracy : ± 5ppb (25 ℃)
•Response Time: <1min
•Probe Life: 7*24hours >2.0 years (depending on the water quality)
•Cable Length: 200cm
•Signal Connector: Isolated 4-20mA
•Measurement Accuracy: ±5ppb@25℃
•Dimension: 42mm*32mm/1.66*1.26in -
•Probe Type: Industrial Grade
•Detection Range: 0~14
•Temperature Range: 0~60°C
•Accuracy : ± 0.1pH (25 ℃)
•Response Time: <1min
•Probe Life: 7*24hours >1.0 years (depending on the water quality)
•Cable Length: 500cmSignal Conversion Board
•Probe Connector: BNC
•Signal Connector: PH2.0-3P
•Measurement Accuracy: ±0.1@25℃
•Dimension: 42mm*32mm/1.66*1.26in -
•Indicator Electrode: Platinum
•Reference Electrode: silver-silver chloride
•Suitable Temperature: 5-70℃
•Electrode Potential: 245mV ~ 270mV
•Reference Electrode Internal Resistance: ≤10KΩ
•Electrode Stability: ±8mV/24hORP Signal Converter
•Input Interface: 5.08mm/0.20" Pluggable Connector
•Measuring Range: -2000mV ~ +2000mV
•Output Interface: PH2.0 - 3Pin
•Module Size: 42mm×32mm/1.65×1.26" -
•Cell Constant: 1.0
•Support Detection Range: 0~20ms/cm
•Recommended Detection Range: 1~15ms/cm
•Temperature Range: 0~60°C
•Probe Life: 7*24hours >1.0 years (depending on the water quality)
•Cable Length: 100cmSignal Conversion Board
•Probe Connector: BNC/Spade
•Signal Connector: PH2.0-3Pin
•Measurement Accuracy: ±5% F.S.
•Board size: 42mm*32mm/1.65in*1.26in -
• Type: Galvanic Probe
• Detection Range: 0~100 mg/L
• Temperature Range: 0-99 ℃
• Response Time: Up to 98% full response, within 90 seconds (25℃)
• Pressure Range: 0~300 PSI
• Electrode Service Life: 4 years (normal use)
• Maintenance Period:
• Membrane Cap Replacement Period:
12 months (in clean water)
• Cable Length: 2 meters
• Probe Connector: BNC
Signal Converter Board
• Cable Connector: BNC/Spade
• Signal Connector: Gravity Analog Interface (PH2.0-3P)
• Dimension: 42mm * 32mm/1.65 * 1.26 inches -
•±0.5°C Accuracy from -10°C to +85°C
•Usable temperature range: -55 to 125°C (-67°F to +257°F)
•9 to 12 bit selectable resolution
•Uses 1-Wire interface- requires only one digital pin for communication
•Unique 64 bit ID burned into the chip
•Multiple sensors can share one pin
•Temperature-limit alarm system
•Query time is less than 750ms
•3 wires interface:
•Stainless steel tube 6mm diameter by 35mm long
•Cable diameter: 4mm (0.16)
•Length: 500cm (196.8")
Outputs
Powered Mechanical Relays
Pre-powered on circuit board switching line voltage
All relays are fused together as one group, total current must not exceed 6A (resistive)(93W)
4 - 20 mA
Internally powered, Fully isolated
600 Ohm max resistive load, Resolution 0.0015% of span
Accuracy ± 0.5% of reading
Mechanical (Controller V2)
Enclosure Material: ABS
Dimensions 145 x 195 x 110 mm
Display: 4.3” 480 x 272 LCD TFT Touch Display Panel Capacitive
Ambient Temperature -4 to 131°F (-20 to 55°C)
Storage Temperature -4 to 176°F (-20 to 80°C)
Mechanical (Controller V1)
Enclosure Material: PETG
Dimensions 120 x 120 x 60 mm
Display: LCD 2004 display module
Ambient Temperature -4 to 131°F (-20 to 55°C)
Storage Temperature -4 to 176°F (-20 to 80°C)